Dr. Nagendra K. Sharma
Associate Professor, School of Chemical Sciences
Email: nagendra@niser.ac.in
Bighnaraj Samantasinghar
(Junior Project Scientist, CIS)
Email: cis.support3@niser.ac.in
Broadband mass resolving power up to 40,000
1 ppm mass accuracy
MS/MS data sets can be acquired with up to 1000 Hz
laser repetition rate from low fmol levels
Laser focus diameters down to 10 µm for high spatial resolution imaging
Dr. Kartikeswar Senapati
Associate Professor, School of Physical Sciences
Email: kartik@niser.ac.in
Bighnaraj Samantasinghar
(Junior Project Scientist, CIS)
Email: cis.support3@niser.ac.in
Acceleration voltage Range: 0.02–30 kV
Adjustment: Continuously variable in 10 Volt steps.
Probe current 40 nA configuration: 3 pA – 40 nA
Magnification Range: 12x – 2,000,000x referenced to Polaroid 5" × 4.5" image format.
Electron source Filament: Schottky field emitter.
Indicators: Status information to indicate all emitter parameters
Prof. Himansu Sekhar Bishwal
Professor, School of Chemical Sciences
Email: himansu@niser.ac.in
Mirza Salim Beg
Junior Project Scientist, CIS
Email: cis.support2@niser.ac.in
Spectral Range- : It has a standard KBr beam splitter and in optional NIR, MIR, FIR, UV and VIS Region, DLaTGS & MCT detectors, and MIR source and we can achieve a spectral range of MIR 8000- 350cm-1. Spectral resolution : >0.16cm-1
Dr. Nagendra K. Sharma
Associate Professor, School of Chemical Sciences
Email: nagendra@niser.ac.in
Prof. Palok Aich
Professor, School of Biological Sciences
Email: palok.aich@niser.ac.in
Dr. Sunayana Kashyap
Project Scientist, CIS
Email: sunayanakashyap.cis@niser.ac.in
Make: Sciecx
Model: TTOF 6600
Mass range TOF = 5 – 40,000 m/z
Mass selection range Q1 = 5 – 2250 m/z
TOF-MS mass resolution and acquisition speed ≥35,000 (FWHM) at 956 m/z, using 10 ms accumulationtime.
TOF-MS/MS mass resolution and acquisition speed ≥ 30,000 (FWHM) at 813 m/z, and ≥25,000 (FWHM) at 195 m/z, using 10 ms accumulation time.
Detector type = 4-channel MCP detector with ADC signal processing for extended dynamic range.
Prof. Subhankar Bedanta,
Professor, School of Physical Scineces
Email: sbedanta@niser.ac.in
Dr. Tapas Ghosh
Scientific Assistant - C, CIS
Email: tapas@niser.ac.in
Gatan Precession Ion Polishing System (PIPS)
Well Diamond wire Shaw
Struers Grinding Mechine
Gatan Dimple grinder
Gatan Plasma Cleaner
Prof. Jogendra Nath Behera
Professor, School of Chemical Sciences
Email: jnbehera@niser.ac.in
Bighnaraj Samantasinghar
Junior Project Scientist, CIS
Email: bighnaraj.cis@niser.ac.in
Magnification: 80X
Dr. Kartikeswar Senapati
Associate Professor, School of Physical Sciences
Email: kartik@niser.ac.in
Mirza Salim Beg
Junior Project Scientist, CIS
Email: mirza.cis@niser.ac.in
Magnification: 60X
Dr. Asima Bhattacharyya
Associate Professor, School of Chemical Sciences
Email: asima@niser.ac.in
Dr. Padmalochan Panda
Post Doctoaral Fellow, CIS
Email: plpanda.cis@niser.ac.in
equipped with DS-Qi2 (16 MP CHOS sensor, capable of monochromatic imaging)
and DS-fi3 (5.9MP CHOS sensor) camera, four different filters and Differential interference
contrast microscopy (DIC).
Magnification 1000x
Dr. Ramanujam Srinivasan
Associate Professor, School of Chemical Sciences
Email: rsrini@niser.ac.in
Dr. Tapas Ghosh
Scientific Assistant - C, CIS
Email: tapas@niser.ac.in
With the following sub-unit:
Leica EM ICE Light Stimulation,
EM GP,
Cryo CLEM DM6 FS,
Cryo CLEM set with 5L Dewar,
Leica EM AFS2 Freeze sub-system,
EM UC7 Basic instrument,
Leica EM FC7 for EM VCT100 cryo transfer,
Leica EM KMR3 Glass knife maker
Prof. Moloy Sarkar
Professor, School of Chemical Sciences
Email: msarkar@niser.ac.in
Dr. Sunayana Kashyap
Projet Scientist, CIS
Email: sunayanakashyap.cis@niser.ac.in
Equipped with: Time-resolved Fluorescence Measurements with Single Molecule Sensitivity, Fluorescence Lifetime Imaging (FLIM), Fluorescence Cross Correlation Spectroscopy (FCCS).
Time Resolution: 100 picosecond.
Dr. Ramanujam Srinivasan
Associate Professor, School of Chemical Sciences
Email: rsrini@niser.ac.in
Dr. Sunayana Kashyap
Projet Scientist, CIS
Email: sunayanakashyap.cis@niser.ac.in
Equipped with SCMOS Camera (4.2 MP), Four LASER sources of wavelength 405 nm, 488 nm, 568 nm, 640 nm and having the operations 3-D SIM, SIM TIRF, 2-D SIM, Ring TIRF, Photokinetic, Conventional and Live Cell imaging.
Dr. Pratap Kumar Sahoo
Associate Professor, School of Physical Sciences
Email: pratap.sahoo@niser.ac.in
Prof. Himansu Sekhar Biswal
Professor, School of Chemical Sciences
Email: himansu@niser.ac.in
Dr. Padmalochan Panda
Post Doctoaral Fellow, CIS
Email: plpanda.cis@niser.ac.in
LASER: 325 nm, 532 nm, 633 nm, 785 nm, 1064 nm,
Spectral Range: 440 m to 1100 nm,
Spectral Resolution: 0.35 cm-1 at 837 nm 1800 gr/mm grating.
High temperature measurement range: 30C to 1500C
Low temperature measurement range: -196C to 600C
Prof. Sudip Barman
Professor, School of Chemical Sciences
Email: sbarman@niser.ac.in
Dr. Ajaya Nayak
Associate Professor, School of Physical Sciences
Email: ajaya@niser.ac.in
Dr. Tapas Ghosh
Scientific Assistant - C, CIS
Email: tapas@niser.ac.in
Point Resolution: 0.19 nm,
Camera: Gatan OneView (CMOS, 4k*4k),
STEM HAADF Resolution: 0.14 nm
EDS: JEOL JED 2300 series